st'rim kits

360° fat grafting kits

Award innovative device

By the French society
of plastic surgery

DERMO-ADIPOSE TISSUE
>
STRIM kits

St’rim single-use kits: excellence in regenerative medicine
Regenerative medicine relies on high-precision devices to ensure optimal and reproducible results. With this in mind, St’rim kits have been designed, incorporating an innovative approach to fat harvesting and reinjection.

Four models to meet every need
Each kit is optimized for a specific fat transfer application. They feature a patented harvesting cannula with diamond-shaped ports, designed to preserve the natural architecture of adipose tissue. This unique design ensures homogeneous aspiration while maintaining the integrity of adipocytes for improved graft retention.
For reinjection, the kits include cannulas adapted to the type of harvested fat, optimizing cell survival and the uniformity of the transferred volume. This precision ensures perfect graft integration, enhancing both the aesthetics and longevity of the results.

A “Sizing & Equalizing” philosophy in the service of excellence
This innovative concept ensures a perfect balance between harvesting and reinjection, helping to reduce irregularities and optimize the symmetry of results.Thanks to this cutting-edge technology, regenerative medicine professionals have a reliable and high-performance tool, ensuring safe and effective patient care.

St’rim kits thus embody the future of fat transfer, combining innovation, precision, and safety.

what makes ST'RIM KITS so special?

1

COMPOSITION

Comprehensive kit that includes:

  • 1 Harvesting cannula
  • 3 injection cannulas for Volumization (2) and Tissue Regeneration (1)
  • Accesories (needle(s) and/or Female Luer-Lock Connector)
  • Doble blister, ready to use in a surgical setting.

2

INDICATIONS

  • Fat injection with St’rim microcannulas extends the application of lipostructure to the superficial layers of the skin and its minimal invasive properties provide small volume enhancement and less trauma than with a 17 G cannula as per the classic technique.
  • St’rim cannulas may be more suitable for regenerative approaches and have brought improvements in the management of pathologies which were until now difficult to perform with satisfactory results:
  • Significantly higher viability and migration of isolated ASCs comparing with conventionally obtained lipoaspirates and adipocytes maintains a normal histologic structure.

3

efficiency

  • All fat grafting tools in one single kit ready for use
  • Being a disposable kit, the functionality of each component is guaranteed
  • Designed to BE eSTRIM EFFICIENT:
    · 1 Harvesting cannula for an accurate fat SIZING
    · 3 EQUALIZING injection cannulas with optimal fat flow injection for deep and superficial treatments
  • Allows a REPRODUCIBLE TECHNIQUE

4

safety

  • Single-use
  • Sterile

5

the differences

INDICATIONS

Kit designed for grafting the smallest fat units, thanks to the extreme miniaturization of the harvesting device.

composition

  • 1u. – Harvesting cannula (2mmx178mm) with 20 ports (10x 2 sides)
  • 3u. FILLIN Injection cannulas :
    B1 - Fillin 21G x 40mm
    B2 - Fillin 21G x 60mm
    B3 - Fillin 17G x 70mm
  • 3u. Needles:
    C1 - 25G x 25mm
    C2 - 14G x 40mm
  • 1u. Female/Female Luer-Lock Connector

features

DIAMOND-SHAPED ORIFICE
· Precision inspired by watchmaking techniques
· Respect for the natural architecture of adipose tissue

UNIQUE MECHANICAL SEPARATION OF HARVESTED CELLS
· Minimization of cellular stress
· Preservation of their viability

TARGETING THE SMALLEST ADIPOCYTES (= ANTI-INFLAMMATORY)
· Improvement of the harvested product quality
· Possible reinjection with 25G needles

benefits

  • EASE OF USE – simplified 3-step procedure (infiltrate, harvest, inject).
  • ENHANCED PATIENT SAFETY – improved recovery and more natural results thanks to a delicate harvesting method and reduced trauma.
  • MULTIPLE APPLICATIONS – a versatile kit meeting the diverse needs of practitioners (ideal for aesthetic procedures and regenerative medicine).
  • OPTIMIZED RESULTS – High-quality injectable product that preserves the primary architecture of the grafted tissue.

    · Skin quality and radiance improvement (brighter complexion).
    · Reduction in the appearance of wrinkles, acne scars, and stretch marks.
    · Filling of under-eye hollows and temples.

Metrics & References

MODEL

A

B1

B2

B3

C1

C2

mm

2,0

0,8

0,8

1,1

0,5

2,0

GAUGE

14

21

21

17

25

14

mm

178

40

60

70

25

40

PICS2NA1-2

5

INDICATIONS

Microfat grafting for small lipoatrophic or scar areas.

composition

  • 1u. Harvesting cannula (2mm x 90mm OR 2mm x 70mm) with 16 ports (4ports x 4sides) - Similar features to PICKING (2mm x 130mm)
  • 3u. FILLIN Injection cannulas:
    B1 - Fillin 19G x 50mm
    B2 - Fillin 21G x 60mm
    B3 - Fillin 21G x 40mm
  • 2u. Needles:
    C1 - 14G x 40mm
    C2 - 21G x 40mm
  • 1u. Female/Female Luer-Lock Connector

Metrics & References

MODEL

A

B1

B2

B3

C1

C2

mm

2,0

1,0

0,8

0,8

0,8

2,0

GAUGE

14

19

21

21

21

14

mm

70

50

60

40

40

40

PICS2070-2

5

MODEL

A

B1

B2

B3

C1

C2

mm

2,0

1,0

0,8

0,8

0,8

2,0

GAUGE

14

19

21

21

21

14

mm

90

50

60

40

40

40

PICS2090-2

5

INDICATIONS

Microfat grafting for skin rejuvenation and volumizing of face, hands, depressed scars and other small lipoatrophic areas

composition

  • 1u. Harvesting cannula (2mmx130mm) with 8 ports (4ports x 2sides)
  • 3u. FILLIN Injection cannulas:
    B1 - Fillin 19G x 50mm
    B2 - Fillin 21G x 60mm
    B3 - Fillin 21G x 40mm
  • 2u. Needles:
    C1 - 14G x 40mm
    C2 - 21G x 40mm
  • 1u. Female/Female Luer-Lock Connector

Metrics & References

MODEL

A

B1

B2

B3

C1

C2

mm

2,0

1,0

0,8

0,8

0,8

2,0

GAUGE

14

19

21

21

21

14

mm

130

50

60

40

40

40

PICS2130-2

5

INDICATIONS

Macrofat grafting for body contouring, augmentation, hybrid augmentation, lipoatrophy, reconstruction and tissue regeneration.

composition

  • 1u. Harvesting cannula PICKING II (10G / 3,5mm x 220mm) with 18 ports (6ports x 3sides)
  • 3u. FILLIN Injection cannulas:
    B1 - Fillin 12G x 150mm
    B2 - Fillin 14G x 150mm
    B3 - Fillin 17G x 100mm
  • 1u. Ergonomic needle (17G x 70mm) to open the entry-point and perform subincision

Metrics & References

MODEL

A

B1

B2

B3

C1

mm

3,5

2,7

2,0

1,5

1,4

GAUGE

10

12

14

17

17

mm

220

150

150

100

70

PICS3523-2

5

videos

Videos

This website uses cookies. We use cookies to ensure that we give you the best experience on our website to personalise content and adverts and to analyse our traffic. You can check our Privacy policy to get more info.